Reference rendering only. Final appearance is subject to confirmed specifications.

Product Overview

PsychrometricsHumidity SensorsVariable AirflowUSB

Key Features

  • Benchtop Duct Design: Min dimensions 590 mm (D) x 1015 mm (W) x 900 mm (H), featuring an integrated air duct housing the direct expansion evaporator coil.
  • Differential Airflow Instrumentation: Relative humidity and temperature sensors are installed both upstream and downstream of the evaporator to analyze air enthalpy changes.
  • Controlled Forced Air Flow: Equipped with a small variable-speed fan providing adjustable airflow across the duct evaporator coil.
  • Refrigeration Circuit Transducers: Includes high/low pressure gauges, electronic pressure transducers, pressure switch, sight glass, filter dryer, and Thermostatic Expansion Valve (TEV).
  • Circuit Thermal Sensors: Minimum 4 thermocouples positioned across the refrigeration circuit to calculate superheating and sub-cooling.
  • Color-Coded Circuit & LCD Screen: Internationally color-coded piping with onboard LCD display showing live measured parameters.
  • Integrated Workstation: Complete with USB Data Acquisition System, Psychrometric and P-h charting software, branded Desktop PC, and Offline UPS.

Technical Specifications

Benchtop Frame FootprintMin. 590 mm (D) x 1015 mm (W) x 900 mm (H)
Air Conditioning Duct UnitTransparent duct containing evaporator coil and upstream/downstream RH & temperature sensors
Airflow Fan AssemblyVariable-speed fan with manual airflow rate control
Refrigerant TypeR134a or equivalent
Safety Pressure TripsLow Side: Pressure 1 bar, Differential 1 bar; High Side: Pressure 14 bar, Differential 4 bar
Operating Temperature Range+5C to +30C
Operating Relative HumidityMin. 80% at temperatures <30C
Acoustic Sound LevelsMax 75 dB within 200 mm of fan; < 70 dB(A) at 400 mm distance
Power SupplySingle Phase, 220 - 240 VAC, 50Hz
Standards ComplianceManufactured in accordance with latest European Union (EU) directives

Experiment Capabilities

  1. Mastery and application of Psychrometric Charts in air conditioning analysis.
  2. Determination of enthalpy change in the airflow across the duct evaporator coil.
  3. Application and plotting of Pressure-Enthalpy (P-h) Charts.
  4. Determination of superheat and sub-cooling levels.
  5. Determination of Coefficient of Performance (CoP) for air conditioning cycles.
  6. Determination of isentropic and non-isentropic compression stage efficiencies.
  7. Investigation of the effect of airflow rate variations on system CoP.

Standard Accessories